Thermo/Foxboro TVA 1000 PID/FID Vapor
Analyzer
If
you need a fast, accurate and easy-to-use analyzer for portable,
efficient, productive monitoring in industrial hygiene or hazardous
waste applications, look no further. The Foxboro TVA 1000 is the
first over-the-shoulder portable vapor analyzer to offer both
photoionization and flame-ionization detection in a single instrument.
It can be a cost-effective tool in helping you meet today's requirements
for a healthier and safer workplace, as well as a cleaner environment.
With its unique single or dual detector design and
on-board datalogging capability, your overall monitoring time
is reduced because of the number of vapors detected. In addition,
on-board datalogging improves the integrity of the data by eliminating
transcription errors.
With a dynamic range of 0 to 2,000 ppm on the PID
detector and 0 to 50,000 ppm on the FID, the TVA is the unit of
choice for environmental professionals responsible for site investigations
and emergency response requiring both PID and FID capabilities.
Pictured: TVA 1000, TVA 1000 Side View, TVA
1000 Top View Inputs
On site, samples are drawn through the hand-held
probe with the unit's powerful 1 lpm sampling pump. Critical to
productivity, a large number of samples can be obtained quickly
with a response time of three seconds. User-selectable alarms
and on-board diagnostics furnish other essential safeguards.
Built for fast, accurate operation, a large keypad
ensures easy operation, with or without gloves. Datalogging is
activated on the hand-held sample probe. Operations are menu-driven
and displays are easy to read.
Weighing just 12 pounds, the TVA's rechargeable
battery and removable Hydrogen fuel tank allows for up to 6 hours
of continuous operation.
| Specifications: |
 |
| Dynamic Range (PID):
|
0.5-2,000 ppm isobutylene |
| Dynamic Range (FID):
|
0.5-50,000 ppm methane |
| Linear Range (PID): |
0.5-500 ppm isobutylene |
| Linear Range (FID): |
0.5-10,000 ppm methane |
| Detection Limit (PID):
|
100 ppb benzene |
| Detection Limit (FID):
|
300 ppb hexane |
| Accuracy (PID): |
± 1% |
| Accuracy
(FID): |
± 2% |
| Datalogging: |
800-18,000 points mode specific |
| Weight: |
13 pounds (5.8 kg) |
| Battery Type: |
Rechargeable Ni-Cad battery |
| Charging Time: |
16 hrs first charge; 2hr charge/1hr use there after |
| Operating Time: |
Up to 8 hours |
| Sampling Rate: |
1,000 cc/minute |
| Listings: |
FM (Class 1, Div. 1, Groups A,B,C&D Hazardous Location,
Temp. Class T4) CENELEC (Div. 1, Zones I and II Group IIC,
Hazardous Location, Temp. Class T4)* |
 |
| Rental Information: |
| Part Number |
Unit Description |
Daily |
Weekly |
Monthly |
| 405-0033 |
TVA 1000B Vapor Analyzer PID/FID |
$114.00 |
$400.00 |
$1,200.00 |
| 405-0047 |
TVA 1000 Vapor Analyzer PID/FID |
$114.00 |
$400.00 |
$1,200.00 |
Rental
Includes: Thermo/Foxboro TVA 1000 FID/PID Vapor
Analyzer, Instruction Manual, Tygon Tubing (1/8" I.D.
X 1/4" O.D.), Extension Probe, Multi-Tool, Printer/Computer
Cables, Wrist Strap, Water/Particulate Filter, Carrying
Case, AC Adapter, Cable Adapter, Gender Changer.
Purchase Support Accessories: |
| Part Number |
Unit Description |
Price |
| GD37-001-A-17S |
Isobutylene, 100ppm, 17ltr |
$40.00 |
| GD40-004-A-17S |
Methane, 100ppm, 17 ltr |
$40.00 |
| GD98-000-0-17S |
Lab Grade Zero Air, 17 ltr |
$40.00 |
| R-TYC |
Tygon Tubing (1/8" ID X 1/4" OD) |
$1.65/foot |
| 402-0020 |
Loaner Regulator |
No Charge with Rental |
|